S.I. Tech, Inc.Technical Support
     
Web Site Content
 

Quantity of RS-485 multidrop units in a series.

Document: 10111

Category: 2128 RS-485 Multidrop Bit-Driver

Date Posted: 04/07/10

Problem

We are seeking info about 2128-SM-SM RS485 Multidrop to Fiber Single Mode. What is the max number of multidrop 2128-SM-SM in a single fiber optic data line? We are following your typical application: the first Multidrop is connected to the second by a couple of f.o. (from downstream connectors to upstream connectors), the second Multidrop is connected to the third and so on.

Solution

At a speed of 57.6 Kbps, you can connect 16 2128-SM-SM in a series.

Back to Technical Support


Contact Technical Support by Phone: 630.761.3640 or Email: tech@sitech-bitdriver.com
©2015 S.I. Tech, Inc. All copy and images.